File information: | |
File name: | InfSDUHSI0141 U7246A B SD UHS-I Card Compliance Test Application Release Notes (Version 01.41) c2014 [preview InfSDUHSI0141 U7246A B SD UHS-I Card Compliance Test Application Release Notes (Version 01.41) c2014] |
Size: | 110 kB |
Extension: | |
Mfg: | Agilent |
Model: | InfSDUHSI0141 U7246A B SD UHS-I Card Compliance Test Application Release Notes (Version 01.41) c2014 🔎 |
Original: | InfSDUHSI0141 U7246A B SD UHS-I Card Compliance Test Application Release Notes (Version 01.41) c2014 🔎 |
Descr: | Agilent InfSDUHSI0141 U7246A B SD UHS-I Card Compliance Test Application Release Notes (Version 01.41) c20140616 [8].pdf |
Group: | Electronics > Other |
Uploaded: | 25-05-2021 |
User: | Anonymous |
Multipart: | No multipart |
Information about the files in archive: | ||
Decompress result: | OK | |
Extracted files: | 1 | |
File name InfSDUHSI0141 U7246A B SD UHS-I Card Compliance Test Application Release Notes (Version 01.41) c2014 Agilent U7246A/U7246B SD Card UHS-I Compliance Test Application Software Release Notes Agilent U7246A /U7246B Software Version 1.41.0000 Released Date: 16 JUNE 2014 Minimum Infiniium Oscilloscope Baseline Version: 4.60 (9000 and 90000 series) Modifications: 1. Resolved scope model verification issue. Page 1 of 8 Agilent U7246A /U7246B Software Version 1.40.0000 Released Date: 1 JUNE 2014 Minimum Infiniium Oscilloscope Baseline Version: 4.60 (9000 and 90000 series) Modification: 1. Supports for Infiniium Oscilloscope Software version 5.00. Page 2 of 8 Agilent U7246A Software Version 1.33.0000 Released Date: 9 May 2014 Minimum Infiniium Oscilloscope Baseline Version: 4.20 (9000 and 90000 series) Enhancements: 1. Added "Trigger Timeout" option in Configure Tab for user to edit the timeout value. 2. Added Threshold Levels tests (Output High Voltage test, VOH and Output Low Voltage test, VOL) Note: This will be the last version to support Infiniium Oscilloscope Baseline Version 4.20. Page 3 of 8 Agilent U7246A Software Version 1.32.0000 Released Date: 14 Aug 2013 Minimum Infiniium Oscilloscope Baseline Version: 4.20 (9000 and 90000 series) Modifications: 1. Fixed Clock Frequency Verification issue. 2. Fixed the histogram issue that disrupts the eye diagram when histogram source change. 3. Changed the triggering method for Precision Mode Test. 4. Turn off all color setting for signal source. 5. Changed the scaling method for Current Consumption Test. 6. Fixed vertical scaling issue for the tests on CMD Lane. 7. Changed the triggering method for Current Consumption Test. 8. Changed the Timeout value for Current Consumption Test 9. Fixed histogram measurement issue Enhancements: 3. Added "tdCK" and "tdRF" option in Configure Tab for Output Delay and Output Hold Time Compensation feature. 4. Added "Maximum Trial" option in Configure Tab to resend command for Current Consumption Test 5. Made enhancement on Current Consumption Test to avoid "MISSMATCH" error. 6. Added Support for MSOX90000 Series Oscilloscopes Page 4 of 8 Agilent U7246A Software Version 1.31.0000 Released Date: 17 November 2011 Minimum Infiniium Oscilloscope Baseline Version: 3.20 (9000 and 90000 series) Modifications: 1. Change of result display sequence in Rise/Fall Time Relation test. 2. Windows 7 x64 driver for USB Interface of TED Host emulator can be found at: C:\ProgramData\Agilent\Infiniium\Apps\SDUHSITest\App\ConsoleA pps\sd_test_win7_x64\ 3. Change of wait time for SD card slot verification. 4. Using probe calibrated value instead of probe default value. Enhancements: 1. Compatible with Window 7 based Oscilloscope. Page 5 of 8 Agilent U7246 |
Date | User | Rating | Comment |